Mercedes-Benz diagnosis DAS comes with initialization fault (1.1)-1.501.9551. Here, mbstartool technicians offers some useful solutions to try.
Tool used with:
MB STAR C3/ SDconnect C4/ SD C5 CONNECT multiplexer (here is the case with SD C5)
Models:
Mercedes-Bnez W208 ’2003
Error message:
Die Initialisierung des Multiplexers ist fehlgeschlagen (The initialization of the multiplexer failed)
BMP:
Fault (1.1)-1.501.9551
Initialization of diagnosis multiplexer failed
Possible cause:
The link between this diagnosis multiplexer and the diagnostic socket is interrupted
The link between the diagnosis multiplexer and the diagnostic unit is interrupted
The voltage supply at the diagnostic socket (circuit 30 and (or) circuit 31) is faulty
Note:
When using SDconnect, check the connection status using the Toolkit
Analysis from technician :
![]()
pay attention to the icon in the bottom right corner
When the computer starts, connect to the Device 21(SDconnect multiplexer)
The cross “x” there means bad communication or some other causes
Optional solutions for bad communication:
1- cable problem
1) the cable from the car to the mux
you may replace it if the mux is not light on
2) the cable from the laptop to the mux
Go to Local Network Connection
Plug and unplug the SD C5 com port for times to see if there is change in Local Network Connection or not.
If not, change another computer to try again, also in this way.
But, if still not any change in any computer, you may replace the LAN cable with another one to have a try.
2- mux problem
If you still have the same problem, it means that the mux is not ok
you may run star utilities you have 2 ways
1) if you hear the mux ticking means you have to check the car-mux cable
2) if you did not hear mux ticking means the laptop-mux cable is not ok OR the mux is not ok
But if unluckily with all solutions before, please send back your unit to the vendor for repairing.
http://blog.mbstartool.com/2016/03/19/how-to-solve-das-initialization-fault-1-1-1-501-9551/
- Why Vident iEasy300 is a must-have Code Reader for Home Use?
- Four-System Scanners: Vident iLink440 vs. Foxwell NT414 vs. MD802 vs. CRP129
- DAS Developer mode add Cruice control to Vito viano W639
- 12.2017 XDOSXentryOpenShell download for SDconnect, Xentry Connect C5
- SD connect C4 Variant Coding on W220 ESP module
- How to wired connect SD connect C4 to PC via LAN cable
限會員,要發表迴響,請先登入